Effectiveness analysis of papillary thyroid carcinoma (PTC) diagnostics in Holycross Cancer Centre (HCC) in Kielce according to fine needle aspiration biopsy quality assurance program in pathology department between years 2001 and 2012

Introduction

Commonly accepted evaluation of diagnostic test usefulness on the basis of analysis of such factors as sensitivity, specificity and overall accuracy is a prelude to more profound statistic deliberations. Practical meaning of those factors depends on many elements like representativity of FNAB smear and also final microscopic evaluation, tumour type or diameter.

Aim of the study

To evaluate detection of PTC by ultrasound-guided fine needle aspiration biopsy (USG-FNAB).

Material

Between years 2001 and 2012, a group of 26361 patients had thyroid lesions diagnosed by USG-FNAB. At least one carcinoma was diagnosed (including two metastases) in 343 patients. Surgical specimens (SS) revealed 419 malignancies, with 335 PTCs. A diameter of histologically measured PTCs ranged from 0.5 mm to 170mm, where those correctly diagnosed in USG-FNAB was between 3 and 170 mm. Number of false negative (FN) cases ranged from 0 to 16 each year.

Methods

A correlation was sought between mean diameter of PTSc, FN cytologic cases and whole number of PTCs found in surgical specimens, each year, in analyzed period of time.

Results

On the basis of numerical and proportional results of assessed parameters three periods of time can be distinguished in analyzed 12 years. The first one is between years 2001 and 2002. More PTCs with greater diameter were diagnosed with USG-FNAB and the percentage of FN diagnoses was higher than in the rest of the whole analyzed period. Since year 2008 till 2012 the number of FN diagnoses stabilized and reached the percentage value interval between 0 and 5. Strong negative correlation was statistically shown between the percentage of FN diagnoses and elapsed time (R= -0.7591, p=0.0042) as well as between the mean PTC diameter (R= -0.6011, p=0.387) and elapsed time.

Conclusions

Presented data showed that, in the course of time, smaller diameter of PTCs was diagnosed by USG-FNAB and more rarely false diagnoses were given in Holycross Cancer Centre.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Sygut, J., Kowalska, A., Słuszniak, J. et al. Effectiveness analysis of papillary thyroid carcinoma (PTC) diagnostics in Holycross Cancer Centre (HCC) in Kielce according to fine needle aspiration biopsy quality assurance program in pathology department between years 2001 and 2012. Thyroid Res 6 (Suppl 2), A59 (2013). https://doi.org/10.1186/1756-6614-6-S2-A59

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1756-6614-6-S2-A59

Keywords