Skip to main content

Table 4 Sensitivity, specificity, PPV, NPV and accuracy of ACR TI-RADS and EU-TIRADS, according to FNA recommendation

From: Analysis of 665 thyroid nodules using both EU-TIRADS and ACR TI-RADS classification systems

 

ACR TI-RADS

EU-TIRADS

Nodules with recommendation to FNA

Nodules without recommendation to FNA

Nodules with recommendation to FNA

Nodules without recommendation to FNA

Malignant (n = 16)

14 (TP)

2 (FN)

14 (TP)

2 (FN)

Benign (n = 59)

43 (FP)

16 (TN)

48 (FP)

11 (TN)

Total (n = 75)

57

18

62

13

Sensitivity

87.5%

87.5%

Specificity

27.1%

18.6%

PPV

24.6%

22.6%

NPV

88.9%

84.6%

Accuracy

40%

33.3%

  1. FN False negatives, FNA Fine-needle aspiration, FP False positives, NPV Negative predictive value, PPV Positive predictive value, TN True negatives, TP True positives